Ancoris Double TOT Sling System

Simple and Meshless Transvaginal Pelvic Organ Prolapse Repair

FIRST LINE TREATMENT

ANCORIS is a transvaginal sacrospinous ligament anchoring systemto treat women with apical prolapse using a safe, reliable and minimally invasive procedure. It can be used to treat isolated apical defects or to perform a concurrent apical fixation for minimizing the risk of recurrence of a native tissue repair (1).

UNIVERSAL SYSTEM

Considering the patient individual condition and the defect which must be treated, ANCORIS POP Repair System can be inserted to the sacrospinous ligament by two different transvaginal approaches, paravesical or pararectal. The use of ANCORIS provides the possibility to perform apical suspension in a reduced operation duration2.

EFFECTIVE MINIMALLY INVASIVE PROCEDURE

A sacrospinous fixation needs to withstand the high pressures affecting the pelvic floor. Clinical studies have shown that the tissue anchoring systems offer a superior primary fixation compared to suturing devices in terms of pull-out resistance. With the help of anchoring devices such as ANCORIS, the risk of recurrent apical prolapse after sacrospinous fixation can be reduced3,4.

TISSUE ANCHORING SYSTEM TAS

The TAS was developed to provide a reliable fixation to the sacrospinous ligament (SSL). It is composed of a polypropylene anchor with an attached polypropylene suture. The TAS serves to provide:

  • Highest pull-out force and accuracy
  • Reliable fixation
  • Safety with regard to vascular and neural structures
  • Six circumfemtially arranged spikes to provide a reliable fixation
  • Safety Stop to prevent injuries of vascular and neural structures behind the ligament

RETRACTABLE INSERTION GUIDE – RIG

The Retractable Insertion Guide was developed to reach the targeted area for performing an accurate and safe anchor insertion. The configuration of the RIG, with its protective tube, guarantees the integrity of surrounding tissue during the implantation of the TAS into the sacrospinous ligament. With its ergonomic design, small diameter and retractable mechanism for connecting and releasing the anchors, the RIG provides:

  • Precision and safety in surgical maneuvers
  • Reduction of surgical dissection to a minimum
  • Total control of connection and release of TAS anchors

ANCORIS IN PRACTICE

  • Uterine prolapse
  • Vaginal vault prolapse
  • Anterior prolapse with apical defect Posterior prolapse with apical defect
  • Apical support for durable results in anterior and posterior repair

ANCORIS MUST NOT BE USED IN:

  • Fertile women
  • Patients with any active or latent infection of the vagina, cervix or uterus
  • Patients with previous or current vaginal, cervical or uterine cancer
  • Previous, current or planned pelvic radiation therapy
  • Known allergy to polypropylene

The implantation of ANCORIS should be based on a thorough patient assessment along with the patient’s individual characteristics and preferences. The following items must also be considered:

  • ANCORIS must ONLY be used by surgeons experienced in transvaginal pelvic floor reconstruction.

For further precautions and warnings, we refer to our Instruction for Use


Related Documentation


Related Specialty